CPU CR20 AC/DC/Relais – SIMATIC S7-200 SMART
CPU compacte SIMATIC S7-200 SMART CR20 avec E/S intégrées, alimentation AC, mémoire 20 KB, programmation STEP 7 Micro/WIN SMART.
Disponible sur demande
SKU: 6ES7288-1CR20-0AA1
Description
CPU CR20 AC/DC/Relais – SIMATIC S7-200 SMART
Référence : 6ES7288-1CR20-0AA1
Description WooCommerce
Nom du produit
6ES7288-1CR20-0AA1 (CPU CR20 AC/DC/relai) – SIMATIC S7-200 SMART
Type exact de produit
CPU CR20 AC/DC/relay
Caractéristiques vérifiées et différences pertinentes
- Onboard I/O: 12 DI 24V DC; 8 DO RELAY 2A
- Alimentation: AC 85-264 V AC, 47-63 Hz (desktop) ; plage de valeur CA: 85-264 V, 230 V nommée
- Mémoire: 20 KB (programme/données); type de mémoire: DDR; Flash présent
- Architecture et options: Programmation via STEP 7 Micro/WIN SMART; rail DIN standard
- Températures et sécurité électrique: protection inversement polaire No; plage DC 5-250 V; tension DC nominale 24 V; consommation 60 mA (à 220 V AC) et 80 mA (à 220 V AC); perte de puissance 6 W
- Caractéristiques temporelles: timing et performances par instruction (ex: 150 ns/instruction, 1.2 µs, 3.6 µs selon les groupes); horloge logicielle
- Interfaces et protocoles: RS 485 (jusqu’à 187.5 kbps); connecteur 9 broches Sub‑D; protections et diagnostics
| Désignation de type du produit | CPU CR20 AC/DC/Relais – SIMATIC S7-200 SMART |
| Référence produit | 6ES7288-1CR20-0AA1 |
| Catégorie | Automatisation → Automates programmables |
| Product type designation | CPU CR20 AC/DC/relay |
| ● Programming package | STEP 7 Micro/WIN SMART |
| Rail mounting | Yes; Standard – DIN rail |
| Rated value (AC) | 230 V; 230 V AC (L1, N) |
| ● 120 V AC | Yes; 85 to 132 V AC |
| ● 230 V AC | Yes; 170 to 264 V AC |
| permissible range, lower limit (AC) | 85 V |
| permissible range, upper limit (AC) | 264 V |
| Reverse polarity protection | No |
| ● permissible range, lower limit | 47 Hz |
| ● permissible range, upper limit | 63 Hz |
| ● Rated value (DC) | 24 V; DC at 4 mA nominal |
| ● permissible range, lower limit (DC) | 5 V |
| ● permissible range, upper limit (DC) | 250 V |
| Current consumption (rated value) | 60 mA; At 220 V AC |
| Current consumption, max. | 80 mA; At 220 V AC |
| Inrush current, max. | 16.3 A; at 264 V |
| Power loss, max. | 6 W |
| Type of memory | DDR |
| Flash | Yes |
| RAM | Yes |
| Micro Memory Card | No |
| for bit operations, typ. | 150 ns; / instruction |
| for word operations, typ. | 1.2 µs; / instruction |
| for floating point arithmetic, typ. | 3.6 µs; / instruction |
| Integrated power supply | No |
| ● Type | Software clock |
| ● Hardware clock (real-time) | No |
| Number of digital inputs | 12; Integrated |
| ● of which inputs usable for technological functions | 4; HSC: 4 @ 100 kHz single phase, 2 @ 50 kHz A/B phase |
| Sourcing/sinking input | Yes |
| ● Type of input voltage | DC |
| ● for signal “0” | < 5 V DC |
| ● for signal “1” | +15 to +30 V |
| ● for signal “0”, max. (permissible quiescent current) | 1 mA |
| ● for signal “1”, typ. | 4 mA |
| — parameterizable | Yes; 0.2 µs, 0.4 µs, 0.8 µs, 1.6 µs, 3.2 µs, 6.4 µs and 12.8 µs, selectable in 4 groups |
| — at “0” to “1”, min. | 0.2 µs |
| — at “0” to “1”, max. | 12.8 µs |
| ● shielded, max. | 500 m |
| ● unshielded, max. | 300 m |
| Number of digital outputs | 8; Relays |
| ● with resistive load, max. | 2 A |
| ● on lamp load, max. | 30 W; 30 W with DC, 200 W with AC |
| ● “0” to “1”, max. | 10 ms; max. |
| ● “1” to “0”, max. | 10 ms; max. |
| ● of the pulse outputs, with resistive load, max. | 1 Hz |
| ● Number of relay outputs | 8 |
| ● Number of operating cycles, max. | 10 000 000; mechanically 10 million, at rated load voltage 100 000 |
| Number of industrial Ethernet interfaces | 0 |
| Number of RS 485 interfaces | 1 |
| Optical interface | No |
| Interface type | RS 485 (max. 187.5 kbps) |
| Isolated | Yes; 500 V AC or 707 V DC |
| ● RS 485 | Yes |
| ● Design of the connection | 9-pin sub D socket |
| Supports protocol for PROFINET IO | No |
| PROFIBUS | No |
| ● TCP/IP | No |
| ● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 | Yes |
| — Test voltage at air discharge | 8 kV |
| — Test voltage at contact discharge | 4 kV |
| ● Interference immunity against high-frequency radiation acc. to IEC 61000-4-3 | Yes; 10 V/m, 80 to 1 000 MHz (to IEC 61000-4-3); 10 V/m, 900 MHz, 1.89 GHz, 50% ED (to IEC 61000-4-3) |
| — Frequency range of the RF radiation | 10 V/m for 80 MHz ~ 1 GHz, 3 V/m for 1.4 GHz ~ 2 GHz, 3 V/m for 87 MHz ~ 108 MHz, 174 MHz ~ 230 MHz, 470 MHz ~ 790 MHz, 1.4 GHz ~ 2 GHz, 1 V/m for 2 GHz ~ 2.7 GHz |
| ● Interference immunity on supply lines acc. to IEC 61000-4-4 | Yes; ±2 kV acc. to IEC 61000-4-4, burst; surge measurements with additional protective elements |
| ● Interference immunity on signal cables acc. to IEC 61000-4-4 | Yes; ±2 kV acc. to IEC 61000-4-4, Burst |
| ● Interference immunity on supply lines acc. to IEC 61000-4-5 | Yes; ±1 kV (acc. to IEC 61000-4-5; 1995; surge symm.), ±2 kV (acc. to IEC 61000-4-5; 1995; surge asymm.), no external protective circuit required |
| — Test voltage on supply cables | 2 kV |
| — Test voltage on signal cables >30m | 2 kV |
| ● Interference immunity against high frequency current feed acc. to IEC 61000-4-6 | Yes; 10 V, 150 kHz to 80 MHz (to IEC 61000-4-6) |
| ● Limit class A, for use in industrial areas | Yes; Emission of radio interference acc. to EN 61000-6-4 +A1 for use in industrial environments |
| ● Interference emission via line/AC current cables | EN 61000-6-4, interference emission: Intended for use in industrial areas. |
| IP degree of protection | IP20 |
| CE mark | Yes |
| ● Fall height, max. | 0.5 m; five times, in product package |
| ● min. | -40 °C |
| ● max. | 70 °C |
| ● horizontal installation, min. | 0 °C |
| ● horizontal installation, max. | 55 °C |
| ● vertical installation, min. | 0 °C |
| ● vertical installation, max. | 45 °C |
| ● Storage/transport, min. | 660 hPa |
| ● Storage/transport, max. | 1 080 hPa |
| ● Installation altitude, min. | -1 000 m |
| ● Installation altitude, max. | 2 000 m |
| ● Operation at 25 ℃ without condensation, max. | 95 % |
| — LAD | Yes |
| — FBD | Yes |
| — STL | Yes |
| Width | 90 mm |
| Height | 100 mm |
| Depth | 81 mm |
| Weight, approx. | 365 g; approx. |
| Onboard I/O | 12 DI 24V DC; 8 DO RELAY 2A |
| Alimentation | AC 85-264 V AC, 47-63 Hz (desktop) ; plage de valeur CA: 85-264 V, 230 V nommée |
| Mémoire | 20 KB (programme/données); type de mémoire: DDR; Flash présent |
| Architecture et options | Programmation via STEP 7 Micro/WIN SMART; rail DIN standard |
| Températures et sécurité électrique | protection inversement polaire No; plage DC 5-250 V; tension DC nominale 24 V; consommation 60 mA (à 220 V AC) et 80 mA (à 220 V AC); perte de puissance 6 W |
| Caractéristiques temporelles | timing et performances par instruction (ex: 150 ns/instruction, 1.2 µs, 3.6 µs selon les groupes); horloge logicielle |
| Interfaces et protocoles | RS 485 (jusqu’à 187.5 kbps); connecteur 9 broches Sub‑D; protections et diagnostics |
Additional information
| Désignation de type du produit | CPU CR20 AC/DC/Relais – SIMATIC S7-200 SMART |
|---|---|
| Référence produit | 6ES7288-1CR20-0AA1 |
| Catégorie | Automatisation → Automates programmables |
| Product type designation | CPU CR20 AC/DC/relay |
| Programming package | STEP 7 Micro/WIN SMART |