CPU CR40 SIMATIC S7-200 SMART
SIMATIC S7-200 SMART CPU CR40s – CPU compacte AC/DC/RELAY avec E/S intégrées et mémoire de 20 KB, montage sur rail DIN, compatible STEP 7 Micro/WIN SMART.
Disponible sur demande
SKU: 6ES7288-1CR40-0AA1
Description
CPU CR40 SIMATIC S7-200 SMART
Produit
Type exact: CPU CR40 AC/DC/Relay (SIMATIC S7-200 SMART)
Caractéristiques vérifiées
- CPU CR40 AC/DC/Relay, COMPACT CPU avec E/S intégrées: 24 DI 24V DC; 16 DO RELAY 2A
- Alimentation: AC 85-264 V AC, 47-63 Hz (230 V AC nominale pour L1/N)
- Mémoire: 20 KB (DDR, Flash disponible)
- Package programmation: STEP 7 Micro/WIN SMART
- Montage sur rails: Oui, standard – rail DIN
- Entrée(s) et plage de tension: 230 V AC (L1, N); 85-132 V AC; 170-264 V AC
- Plage admissible (AC): 85 V à 264 V; Fréquence 47 Hz à 63 Hz
- Plage admissible (DC): 5 V à 250 V
- Consommation: 80 mA (à 220 V AC); max 100 mA (à 220 V AC); pertes ≤ 8 W
- Mémoire et vitesse: mémoire DDR; délais internes mentionnés (ex. 150 ns / instruction, 1.2 µs / instruction, 3.6 µs / instruction)
- Protection et interface: pas de protection inverse de polarité; RS 485 (max. 187,5 kbps); connecteur 9 broches D-sub
- Compatibilités & conditions: fourniture logique DC; horloge logicielle disponible; horloge interne non indiquée comme additionnelle
| Désignation de type du produit | CPU CR40 SIMATIC S7-200 SMART |
| Référence produit | 6ES7288-1CR40-0AA1 |
| Catégorie | Automatisation → Automates programmables |
| Product type designation | CPU CR40 AC/DC/Relay |
| ● Programming package | STEP 7 Micro/WIN SMART |
| Rail mounting | Yes; Standard – DIN rail |
| Rated value (AC) | 230 V; 230 V AC (L1, N) |
| ● 120 V AC | Yes; 85 to 132 V AC |
| ● 230 V AC | Yes; 170 to 264 V AC |
| permissible range, lower limit (AC) | 85 V |
| permissible range, upper limit (AC) | 264 V |
| Reverse polarity protection | No |
| ● permissible range, lower limit | 47 Hz |
| ● permissible range, upper limit | 63 Hz |
| ● Rated value (DC) | 24 V |
| ● permissible range, lower limit (DC) | 5 V |
| ● permissible range, upper limit (DC) | 250 V |
| Current consumption (rated value) | 80 mA; At 220 V AC |
| Current consumption, max. | 100 mA; At 220 V AC |
| Inrush current, max. | 16.3 A; at 264 V |
| Power loss, max. | 8 W |
| Type of memory | DDR |
| Flash | Yes |
| RAM | Yes |
| Micro Memory Card | No |
| for bit operations, typ. | 150 ns; / instruction |
| for word operations, typ. | 1.2 µs; / instruction |
| for floating point arithmetic, typ. | 3.6 µs; / instruction |
| Integrated power supply | No |
| ● Type | Software clock |
| ● Hardware clock (real-time) | No |
| Number of digital inputs | 24; Integrated |
| ● of which inputs usable for technological functions | 4; HSC: 4 @ 100 kHz single phase, 2 @ 50 kHz A/B phase |
| Sourcing/sinking input | Yes |
| ● Type of input voltage | DC |
| ● for signal “0” | < 5 V DC |
| ● for signal “1” | +15 to +30 V |
| ● for signal “0”, max. (permissible quiescent current) | 1 mA |
| ● for signal “1”, typ. | 4 mA |
| — parameterizable | Yes; 0.2 µs, 0.4 µs, 0.8 µs, 1.6 µs, 3.2 µs, 6.4 µs and 12.8 µs, selectable in 4 groups |
| — at “0” to “1”, min. | 0.2 µs |
| — at “0” to “1”, max. | 12.8 µs |
| ● shielded, max. | 500 m |
| ● unshielded, max. | 150 m |
| Number of digital outputs | 16; Relays |
| ● with resistive load, max. | 2 A |
| ● on lamp load, max. | 30 W; 30 W with DC, 200 W with AC |
| ● “0” to “1”, max. | 10 ms; max. |
| ● “1” to “0”, max. | 10 ms; max. |
| ● of the pulse outputs, with resistive load, max. | 1 Hz |
| ● Number of relay outputs | 16 |
| ● Number of operating cycles, max. | 100 000; mechanically 10 million, at rated load voltage 100 000 |
| Number of industrial Ethernet interfaces | 0 |
| Number of RS 485 interfaces | 1 |
| Optical interface | No |
| Interface type | RS 485 (max. 187.5 kbps) |
| Isolated | Yes; 500 V AC or 707 V DC |
| ● RS 485 | Yes |
| ● Design of the connection | 9-pin sub D socket |
| PROFINET IO | No |
| PROFIBUS | No |
| ● TCP/IP | No |
| ● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 | Yes |
| — Test voltage at air discharge | 8 kV |
| — Test voltage at contact discharge | 4 kV |
| ● Interference immunity against high-frequency radiation acc. to IEC 61000-4-3 | Yes; 10 V/m, 80 to 1 000 MHz (to IEC 61000-4-3); 10 V/m, 900 MHz, 1.89 GHz, 50% ED (to IEC 61000-4-3) |
| — Frequency range of the RF radiation | 10 V/m for 80 MHz ~ 1 GHz, 3 V/m for 1.4 GHz ~ 2 GHz, 3 V/m for 87 MHz ~ 108 MHz, 174 MHz ~ 230 MHz, 470 MHz ~ 790 MHz, 1.4 GHz ~ 2 GHz, 1 V/m for 2 GHz ~ 2.7 GHz |
| ● Interference immunity on supply lines acc. to IEC 61000-4-4 | Yes; 2 kV acc. to IEC 61000-4-4, burst |
| ● Interference immunity on signal cables acc. to IEC 61000-4-4 | Yes; ±2 kV acc. to IEC 61000-4-4, Burst |
| ● Interference immunity on supply lines acc. to IEC 61000-4-5 | Yes; ±1 kV (acc. to IEC 61000-4-5; 1995; surge symm.), ±2 kV (acc. to IEC 61000-4-5; 1995; surge asymm.), no external protective circuit required |
| — Test voltage on supply cables | 2 kV |
| — Test voltage on signal cables >30m | 2 kV |
| ● Interference immunity against high frequency current feed acc. to IEC 61000-4-6 | Yes; 10 V, 150 kHz to 80 MHz (to IEC 61000-4-6) |
| ● Limit class A, for use in industrial areas | Yes; EN 61000-6-4, interference emission: Intended for use in industrial areas. |
| ● Interference emission via line/AC current cables | EN 61000-6-4, interference emission: Intended for use in industrial areas. |
| IP degree of protection | IP20 |
| CE mark | Yes |
| ● Fall height, max. | 0.5 m; five times, in product package |
| ● min. | -40 °C |
| ● max. | 70 °C |
| ● horizontal installation, min. | 0 °C |
| ● horizontal installation, max. | 55 °C |
| ● vertical installation, min. | 0 °C |
| ● vertical installation, max. | 45 °C |
| ● Storage/transport, min. | 660 hPa |
| ● Storage/transport, max. | 1 080 hPa |
| ● Installation altitude, min. | -1 000 m |
| ● Installation altitude, max. | 2 000 m |
| ● Operation at 25 ℃ without condensation, max. | 95 % |
| — LAD | Yes |
| — FBD | Yes |
| — STL | Yes |
| Width | 125 mm |
| Height | 100 mm |
| Depth | 81 mm |
| Weight, approx. | 475 g; approx. |
| Type exact | CPU CR40 AC/DC/Relay (SIMATIC S7-200 SMART) |
| CPU CR40 AC/DC/Relay, COMPACT CPU avec E/S intégrées | 24 DI 24V DC; 16 DO RELAY 2A |
| Alimentation | AC 85-264 V AC, 47-63 Hz (230 V AC nominale pour L1/N) |
| Mémoire | 20 KB (DDR, Flash disponible) |
| Package programmation | STEP 7 Micro/WIN SMART |
| Montage sur rails | Oui, standard – rail DIN |
| Entrée(s) et plage de tension | 230 V AC (L1, N); 85-132 V AC; 170-264 V AC |
| Plage admissible (AC) | 85 V à 264 V; Fréquence 47 Hz à 63 Hz |
| Plage admissible (DC) | 5 V à 250 V |
Additional information
| Désignation de type du produit | CPU CR40 SIMATIC S7-200 SMART |
|---|---|
| Référence produit | 6ES7288-1CR40-0AA1 |
| Catégorie | Automatisation → Automates programmables |
| Product type designation | CPU CR40 AC/DC/Relay |
| Programming package | STEP 7 Micro/WIN SMART |
| Rail mounting | Yes; Standard – DIN rail |